• Port Size: 3/8 (F) NPT
• Maximum Airflow: 3/8: 78 SCFM
• Maximum Working Pressure: 200 PSI
• Pressure Range: 7-170 PSI
• Working Temperature: -10 to 70 °C
• Filtration: 5 microns
• Drain: Semi-automatic
• Bowl Capacity: Filter/regulator: 110 ml, Lubricator: 130 ml
• Pressure Gauge Port Size: 1/4 (F) BSPP
• Replacement Element: 51.695
• Replacement Gauge: 55.798
Material(s):
• Body Material(s): Stainless Steel
• Bowl Type: Polycarbonate with steel guard
• Bowl Guard: Steel
• Regulation Type: Relieving
• Filter Element: Polyethylene, 5 microns
• Deflector & Spinner: ABS
• O-Rings & Seals: EPDM rubber
• Regulator Cap: Reinforced nylon
• Diaphragm: EPDM rubber
• Poppet Valve: Brass and rubber
• Regulator Spring: Stainless steel
• Lubricator Sight Gauge: Polycarbonate
• Fill Plug: ABS
• Retainer: ABS
• Lubricator Adjusting Knob: ABS
• Check Flap: Polyurethane
• Stainless steel SUS 316 body and bowl
• Compact design with space saving integrated F/R
• Accurate pressure control
• Removes contaminants down to 5 microns in size
• Standard semi-automatic drain
• Lubricator refillable under pressure
• Pressure gauge and mounting brackets included
WHERE TO INSTALL A FILTER
Install the filter as far as possible from the compressor to allow the compressed air to cool and water vapors to condense. Removal of water in liquid form is more effective than removing water which is vapor form.
Install the filter closest to the tool and before the lubricator and regulator
Always install the filter with the arrows pointing to the tool or application
WHERE TO INSTALL A REGULATOR
Install the regulator on each pipe where applications and air tools requires different working pressure
Always install the regulator downstream of a filter and upstream of a lubricator
Can be installed vertically or horizontally
Always install regulator with the arrows pointing to the tool or application
WHERE TO INSTALL A LUBRICATOR
Install as close to the tool as possible, within 5 meters or 30 meters for micro-fog type lubricators
Always install downstream of a filter and a regulator
Ensure that the lubricator is easily accessible for filling pneumatic tool oil
Always install with the arrows pointing to the tool or application
• Port Size: 3/8 (F) NPT
• Maximum Airflow: 3/8: 78 SCFM
• Maximum Working Pressure: 200 PSI
• Pressure Range: 7-170 PSI
• Working Temperature: -10 to 70 °C
• Filtration: 5 microns
• Drain: Semi-automatic
• Bowl Capacity: Filter/regulator: 110 ml, Lubricator: 130 ml
• Pressure Gauge Port Size: 1/4 (F) BSPP
• Replacement Element: 51.695
• Replacement Gauge: 55.798
Material(s):
• Body Material(s): Stainless Steel
• Bowl Type: Polycarbonate with steel guard
• Bowl Guard: Steel
• Regulation Type: Relieving
• Filter Element: Polyethylene, 5 microns
• Deflector & Spinner: ABS
• O-Rings & Seals: EPDM rubber
• Regulator Cap: Reinforced nylon
• Diaphragm: EPDM rubber
• Poppet Valve: Brass and rubber
• Regulator Spring: Stainless steel
• Lubricator Sight Gauge: Polycarbonate
• Fill Plug: ABS
• Retainer: ABS
• Lubricator Adjusting Knob: ABS
• Check Flap: Polyurethane
• Stainless steel SUS 316 body and bowl
• Compact design with space saving integrated F/R
• Accurate pressure control
• Removes contaminants down to 5 microns in size
• Standard semi-automatic drain
• Lubricator refillable under pressure
• Pressure gauge and mounting brackets included
WHERE TO INSTALL A FILTER
Install the filter as far as possible from the compressor to allow the compressed air to cool and water vapors to condense. Removal of water in liquid form is more effective than removing water which is vapor form.
Install the filter closest to the tool and before the lubricator and regulator
Always install the filter with the arrows pointing to the tool or application
WHERE TO INSTALL A REGULATOR
Install the regulator on each pipe where applications and air tools requires different working pressure
Always install the regulator downstream of a filter and upstream of a lubricator
Can be installed vertically or horizontally
Always install regulator with the arrows pointing to the tool or application
WHERE TO INSTALL A LUBRICATOR
Install as close to the tool as possible, within 5 meters or 30 meters for micro-fog type lubricators
Always install downstream of a filter and a regulator
Ensure that the lubricator is easily accessible for filling pneumatic tool oil
Always install with the arrows pointing to the tool or application